SYS · 05SIA 271 / 272POS. 05← Alle Systeme

Remediation of existing waterproofing

Expert assessment, leak tracing and repair of existing systems without full removal where possible. Thermography and smoke testing included.

01 · Systemdaten
Norm
SIA 271 / 272
System-Code
POS. 05
Substrate
Existing bitumen or synthetic membrane
System
System-dependent
Detail-Sheet
DET. 02–05 / 12
02 · Layer build-up

The construction, layer by layer.

  1. POS. 00Existing waterproofing
  2. POS. 01Leak tracing / thermography
  3. POS. 02Primer coat0.2 mm
  4. POS. 03New membraneWATER2 × 4 mm
  5. POS. 04Protection layer6 mm
  6. POS. 05Reinstatement